Preview

Nuclear Physics and Engineering

Advanced search

Electron and Gamma Quantum Source with Energy of 4–10 MeV for Calibration of Nuclear Detectors

https://doi.org/10.56304/S207956292006055X

Abstract

A structural configuration and parameters of a modernized source of electrons and gamma quanta with energy of 4–10 MeV are presented. The source is designed on the basis of electron linac LUE-8-5 RV (INR RAS) and can be used for detector calibration and other practical applications.

About the Authors

G. V. Solodukhov
Institute for Nuclear Research, Russian Academy of Sciences
Russian Federation

Moscow, 117312 



V. N. Ponomarev
Institute for Nuclear Research, Russian Academy of Sciences
Russian Federation

Moscow, 117312 



V. G. Nedorezov
Institute for Nuclear Research, Russian Academy of Sciences
Russian Federation

Moscow, 117312 



References

1. Логутин В.Т. и др. // В сб. Радиационная техника. 1975. Москва: Атомиздат. С. 3–9.

2. de Rocguigny H., Vorogushin M., Demsky M. // Сб. док. Х Международного совещания по применению ускорителей заряженных частиц в промышленности и медицине (С-Петербург, 1–4 октября 2001). 2001. Москва: ЦНИИАТОМИНФОРМ. С. 28–30.

3. Громов А.М., Солодухов Г.В. // Труды ХII Всесоюзного совещания по ускорителям заряженных частиц (Москва, 3–5 октября 1990 г.). Т. II. С. 275– 280. 1992. Дубна.

4. Nedorezov V., Konobeevski E., Polonsky A. et al. // Phys. Scripta. 2019. V. 94 (1). P. 015303. https://doi.org/10.1088/1402-4896/aaed6b

5. Zuyev S.V., Konobeevski E.S., Mordovskoy M.V. et al. // Phys. Part. Nucl. 2019. V. 50 (5). P. 623–625. https://doi.org/10.1134/S1063779619050289

6. Dzhilavyan L.Z., Lapik A.M., Nedorezov V.G. et al. // Phys. Part. Nucl. 2019. V. 50 (5). P. 745–754. https://doi.org/10.1134/S106377961905006X

7. Недорезов В.Г., Савельев-Трофимов А.Б. // Ядерная физика и инжиниринг. 2016. Т. 7. С. 479–486.

8. Gurevich G.M., Lazareva L.E., Mazur V.M. et al. // Nucl. Phys. A. 1981. V. 351. P. 257–268.


Review

For citations:


Solodukhov G.V., Ponomarev V.N., Nedorezov V.G. Electron and Gamma Quantum Source with Energy of 4–10 MeV for Calibration of Nuclear Detectors. Nuclear Physics and Engineering. 2021;12(2):100-102. (In Russ.) https://doi.org/10.56304/S207956292006055X

Views: 46


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 2079-5629 (Print)