Proton Therapy Facility Based on the PNPI SC-1000 Synchrocyclotron. Current Status and Bringing to Modern High-Tech Medical Care Standards

https://doi.org/10.56304/S2079562920060135

Abstract

The stereotactic proton therapy facility at the SC-1000 synchrocyclotron, Petersburg Nuclear Physics Institute, is described. The "shoot-through" irradiation method is applied: intracranial targets are exposed to a 1000-MeV horizontal proton beam in combination with a rotational irradiation technique. Particular attention is paid to the modernization of the facility and the bringing it to modern high-tech medical care standards. The design project of a proton therapy table is described. The features of the developed software for control of the facility and track the parameters of the proton beam, which allows precise positioning, as well as dynamic movement of components for the implementation of complex irradiation plans are considered. It has been found that a unique irradiation technique requires the development of an unparalleled threedimensional treatment planning system to simulate the irradiation conditions, calculation of dose distributions, and selection of the optimal irradiation plan taking into account dose-constraints in organs of risk. It is also required to develop A verification system should also be developed to ensure the quality assurance of proton stereotactic therapy.

About the Authors

D. S. Brozhik
Petersburg Nuclear Physics Institute, National Research Center Kurchatov Institute
Russian Federation

D. S. Brozhik, 

Gatchina, Leningradskaya oblast, 188300.



О. M. Zhidkova
Petersburg Nuclear Physics Institute, National Research Center Kurchatov Institute
Russian Federation

О. M. Zhidkova,

Gatchina, Leningradskaya oblast, 188300.



Е. M. Ivanov
Petersburg Nuclear Physics Institute, National Research Center Kurchatov Institute
Russian Federation

Е. M. Ivanov, 

Gatchina, Leningradskaya oblast, 188300.



D. L. Karlin
Petersburg Nuclear Physics Institute, National Research Center Kurchatov Institute
Russian Federation

D. L. Karlin,

Gatchina, Leningradskaya oblast, 188300.



N. А. Kuzora
Petersburg Nuclear Physics Institute, National Research Center Kurchatov Institute
Russian Federation

N. А. Kuzora, 

Gatchina, Leningradskaya oblast, 188300.



V. I. Maksimov
Petersburg Nuclear Physics Institute, National Research Center Kurchatov Institute
Russian Federation

V. I. Maksimov, 

Gatchina, Leningradskaya oblast, 188300.



N. I. Mamedova
Petersburg Nuclear Physics Institute, National Research Center Kurchatov Institute
Russian Federation

N. I. Mamedova, 

Gatchina, Leningradskaya oblast, 188300.



F. А. Pak
Petersburg Nuclear Physics Institute, National Research Center Kurchatov Institute
Russian Federation

F. А. Pak, 

Gatchina, Leningradskaya oblast, 188300.



А. I. Khalikov
Petersburg Nuclear Physics Institute, National Research Center Kurchatov Institute
Russian Federation

А. I. Khalikov,

Gatchina, Leningradskaya oblast, 188300.



References

1. Granov A.M., Tyutin L.A., Shalek R.A., Vinogradov V.M., Karlin D.L. // Med. fizika. 2016. No. 2 (70). P. 10–17.

2. Abrosimov N.K., Vorobyov A.A., Zherbin E.A., Connonov E.A. // Vestnik Akademii Nauk SSSR. 1985. P. 84–91.

3. Granin D.I., Vasilevskaya I.V., Khalikov A.I., Maksimov V.I. // Med. fizika. 2018. No. 4 (80). P. 17–23.

4. IAEA-TECDOC-1040. 1998. Vienna: IAEA.


Review

For citations:


Brozhik D.S., Zhidkova О.M., Ivanov Е.M., Karlin D.L., Kuzora N.А., Maksimov V.I., Mamedova N.I., Pak F.А., Khalikov А.I. Proton Therapy Facility Based on the PNPI SC-1000 Synchrocyclotron. Current Status and Bringing to Modern High-Tech Medical Care Standards. Nuclear Physics and Engineering. 2021;12(1):64-68. (In Russ.) https://doi.org/10.56304/S2079562920060135

Views: 34


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 2079-5629 (Print)
ISSN 2079-5637 (Online)